2-Port MODBUS TCP to Modbus RTU Protocol Gateway
Front view
Supports 2 x 10/100 Mbit/s MODBUS TCP RJ45 interfaces
Millisecond-level protocol conversion time
Supports 3 x RS485 interfaces
Graphical configuration, no programming required
Supports Modbus device point table import and export
Configuration software can monitor and record Modbus network data online
Complies with standard Modbus protocol specifications
Complies with standard Modbus protocol specificationsFeaturesFeatures
Overview
The IPG66-D2T3S-D2 is an easy-to-configure, high-performance protocol conversion gateway used to connect Modbus RTU serial devices to Modbus TCP networks. The gateway enables bidirectional data exchange, connecting Modbus RTU data as easily processable I/O data to Modbus TCP controllers. On the Modbus side, client/server mode can be switched, and the configuration software is used to establish data mapping between the two sides for cross-protocol data forwarding.
Technical Parameters
| Modbus RTU | |
|---|---|
| Modbus Specification | V1.1b3 |
| Modbus RTU Specification | V1.02 Master/Slave |
| Number of RS485 Interfaces | 3 |
| RS485 Interface | 3-pin terminal |
| Node Scale | 3 x RS485 interfaces, each RS485 interface supports up to 32 Modbus RTU slave devices and up to 128 Modbus commands. The 3 interfaces allow up to 384 Modbus commands in total. |
| RS485 Termination Resistor | Built-in 120Ω termination resistor |
| Supported Baud Rates | 1200 Bits/s, 2400 Bits/s, 4800 Bits/s, 9600 Bits/s, 19200 Bits/s, 38400 Bits/s, 57600 Bits/s, 115200 Bits/s |
| Master/Slave | Master/Slave selectable |
| Parity | Odd, even, none selectable |
| Function Codes | Function codes 01H, 02H, 03H, 04H, 05H, 06H, 0FH, 10H |
| Modbus TCP | |
| Modbus Specification | V1.1b3 |
| Modbus TCP Specification | V1.0b Client/Server |
| Ethernet interface | 2 x RJ45 |
| Node Scale | Client can connect to 16 Modbus TCP Server devices, each device can be configured with 32 Modbus commands; Server supports 10 Modbus TCP Client devices connecting simultaneously. |
| Transformer Isolation | Supported |
| Supported Rates | 10/100M full duplex |
| Mode | Client/Server selectable |
| Parity | CRC |
| Function Codes | Function codes 01H, 02H, 03H, 04H, 05H, 06H, 0FH, 10H |
| Configuration Tool | |
| Configuration Interface | Ethernet interface |
| Project Management | Supports save and load |
| Language | Supports Chinese/English |
| Monitoring | Supports Modbus packet monitoring |
| Modbus Point Table | Supports Modbus point table import and export |
| Data Mapping | Supports mapping configuration |
| Electrical Performance | |
| Power | 24VDC (-15% ~ +20%) 130mA@24VDC |
| Isolation | Triple isolation: Modbus <=> power <=> Ethernet |
| Protection | Reverse voltage/short-circuit protection |
| Operating Temperature | -20℃ ~ +70℃ |
| Storage Temperature | -40℃ ~ +85℃ |
| Relative Humidity | 10 - 95% non-condensing |
| Mechanical | |
| Ingress Protection (IP) Rating | IP20 |
| Enclosure Material | Iron |
| Enclosure Dimensions (Net W x H x D) | 34x 110 x 74 mm |
| Weight | Approx. 330g |
| Mounting | DIN 35mm rail mounting |
| MTBF | MTBF greater than 500,000 hours |
Resources
Ordering Information
| Model | Description |
|---|---|
| IPG66-D2T3S-D2 | DIN-Rail MODBUS TCP to MODBUS RTU protocol gateway, 2 x RJ45 ports to 3 x RS485 serial ports, 24VDC power input |