IPG22-D2T3S-D2
2-Port PROFINET-to-RS232 Gateway
Front view
Port side
DIN-rail
Back view
Power input
Supports 2 x 10/100BaseT(X) Profinet RJ45 interfaces
Millisecond-level protocol conversion time
Complies with standard PROFINET-IO and Modbus protocol specifications and supports custom serial protocols
Supports 3 x RS232 serial ports
Graphical configuration, no programming required
Configuration software can monitor and record Modbus network data online
Overview
The IPG22-D2T3S-D2 is an easy-to-configure, high-performance serial-to-PROFINET gateway supporting bidirectional data exchange, compatible with standard Modbus RTU devices and custom serial protocols. The product is maturely adapted to various industrial device scenarios with RS485 interfaces, such as frequency converters, HV/LV electrical equipment, energy meters, field instruments, PLCs, DCS and FCS.
Technical Parameters
| PROFINET | |
| PROFINET Mode | PROFINET I/O Slave |
| PROFINET Specification | V2.43 |
| GSDML Specification | V2.33 |
| PROFINET Interface | 2 x 10/100BaseT(X) Ethernet, RJ45 connectors |
| Slot | Supports 16 slots |
| MRP | Supported |
| Max. Data Size | 1440bytes IN+1440bytes OUT |
| Switch | Integrated dual-port switch |
| Acyclic Read/Write | Supports acyclic RECORD read/write |
| Ethernet Packet Monitoring | Supported |
| Modbus Packet Monitoring | Supported |
| Protocol Conversion Time | <2ms |
| Serial Port | |
|---|---|
| Modbus Specification | V1.1b3 |
| Modbus RTU Specification | V1.02 |
| RS232 Interface | 3 x 3-pin industrial terminals, software-selectable interface |
| Node Scale | Supports up to 32 Modbus RTU slave devices and up to 128 Modbus commands. Supports up to 128 custom commands |
| RS485 Termination Resistor | DIP switch matching termination resistor (120Ω) |
| Supported Baud Rates | 1200 Bit/s, 2400 Bits/s, 4800 Bits/s, 9600 Bits/s, 19200 Bits/s, 38400 Bits/s, 57600 Bit/s, 115200 Bits/s |
| Modbus RTU Master/Slave | Master/Slave selectable |
| Parity | Odd, even, none selectable |
| Modbus RTU Function Codes | Function codes 01H, 02H, 03H, 04H, 05H, 06H, 0FH, 10H |
| Custom Protocol Communication Model | Request/Response mode |
| Custom Protocol Basic Elements | Constants, variables, checksum |
| Custom Protocol Trigger | Supported, trigger address configurable |
| Configuration Tool | |
| Configuration Interface | Ethernet interface |
| Project Management | Supports save and load |
| Language | Supports Chinese/English switching |
| Monitoring | Supports Modbus packet monitoring, import and export |
| Modbus Point Table | Supports Modbus point table import and export |
| Data Mapping | Supports mapping configuration between serial data and PROFINET-IO |
| Electrical Performance | |
| Power | 24VDC (-15% ~ +20%) 60mA@24VDC |
| Isolation | Triple isolation: serial <=> power <=> Ethernet |
| Protection | Reverse voltage/short-circuit protection |
| Operating Temperature | -20℃ / +70℃ |
| Storage Temperature | -40℃ / +85℃ |
| Relative Humidity | 10 - 95% non-condensing |
| Mechanical | |
| Ingress Protection (IP) Rating | IP20 |
| Enclosure Material | Metal |
| Enclosure Dimensions (Net W x H x D) | 34x 110 x 74 mm |
| Weight | Approx. 330g |
| Mounting | DIN 35mm rail mounting |
| MTBF | MTBF greater than 500,000 hours |
Resources
Ordering Information
| Model | Description |
|---|---|
| IPG22-D2T3S-D2 | DIN-Rail industrial PROFINET-to-RS232 protocol gateway, 3 x RS232 serial ports to 2 x 100M Profinet electrical ports, 24VDC power input |